MENU

VEGA SERIES ( 0-100kW )




    VEGA Load Bank, gives you easy and quick solutions for power requirements up to 100kW. Due to its innovative design, it provides you with the desired power at low temperatures. With portable, Indoor and Outdoor cabin designs, you do not get affected by the environment conditions while conducting your tests.

    VEGA Load Bank is produced with Resistive, Inductive and Mixed Type load options at 380V, 400V and 690V and Medium Voltage; it offers efficient use by means of Manual control, Automatic control, Remote control and PC connection, Data recording and Reporting.

     Usage Areas:  Telecom Companies - Power Plants - Military Institutions - Electric Switch Fields - AC / DC Generator Startup - UPS Systems - Ship and Submarine Power Systems - Prevention of Wet Stacking Problem - Wind Turbine Tests - Solar Energy Systems

    - Resistive / Inductive / Mixed Type Charging

     

    - Long-life Cr-Al Resistance

    - IP23, IP41, IP55 Cabinet Designs

    - Indoor-Outdoor-Portable Steel Cabinet

    - Carrying Handles / Lifting Lugs

    - Forklift Carrying Legs

    - Horizontal Air releases

    - Operation warning light

    - Smart Fan protection system

    - Manual and digital load control

    - Corrosion resistant cabinet

    - Smart Fan protection system

     

    Input Voltage:  380V / 690V 50Hz / 400Hz AC 

     

    Capacity:  0kW - 100 kW 

     

    Load Type: Resistive / Inductive / Resistive+ Inductive

     

    Power Factor: 1

     

    Load Step:  Min. 1kW

     

    Cooling: Thermostatic controlled Air fans

     

     Protections: Over Current, Over Temperature, Phase Failure

     

     Measurements: Current, Voltage, Temperature, Power, Harmonics

     

    Control: Local Control Panel / Remote Control / PC Control

     

    Resistance Temp.: < 300°C 

     

    Air Outlet: < 120°C 

     

     * Dimension and weight changes due to 

    Input Voltage:  380V / 690V 50Hz / 400Hz AC 

     

    Capacity:  0kW - 100 kW 

     

    Load Type: Resistive / Inductive / Resistive+ Inductive

     

    Power Factor: 1

     

    Load Step:  Min. 1kW

     

    Cooling: Thermostatic controlled Air fans

     

     Protections: Over Current, Over Temperature, Phase Failure

     

     Measurements: Current, Voltage, Temperature, Power, Harmonics

     

    Control: Local Control Panel / Remote Control / PC Control

     

    Resistance Temp.: < 300°C 

     

    Air Outlet: < 120°C 

     

     * Dimension and weight changes due to 

     

     

    Remote Control

     

     -PC Connection

     

    -Ability to Prepare Test Scenario

     

    --Special Voltage and Current Values

     

    -SCADA Connection Preface

     

    -MODBUS RTU Communication

     

    -4-20mA Analog Outputs

     

    -0-10V Analog Outputs

     

    -Dry Contact Connections

     

    -Data Recording and Reporting